Lithium-Ion Fires at Sea and the Need to Reassess Escape Planning

25th November 2026
Electric Car Litium Ion Cargo

Battery-powered vehicles, containerised cargo and shipboard equipment are changing the character of fire risk at sea. Emergency plans need to connect accurate cargo information with detection, containment, command decisions and a reliable route to safety. 

Lithium-ion batteries are now part of everyday maritime operations. They arrive on board in electric vehicles, containerised consumer products and replacement battery shipments, as well as in tools, portable equipment and energy storage systems. Their use supports electrification and decarbonisation, yet it also introduces fire scenarios that do not behave like the incidents for which vessel procedures were originally written. 

For shipowners and operators, the core issue is not whether a Lithium-ion battery fire will be more severe than a conventional vehicle or machinery fire.  The more useful question is whether the vessel has enough information to identify the exposure, and whether its detection, containment, command decisions and escape arrangements account for thermal runaway and the toxic environment it creates. 

The consequences are especially significant at sea. A developing incident may be hours or days away from specialist shore-side support, forcing crews to make quick decisions inside a complex structure with limited exit paths, changing ventilation, and people who may not know the ship. Effective fire protection therefore depends on more than suppression. It means giving everyone a reliable route to safe air if primary control measures fail. 

Why Lithium-Ion Fires Demand Different Planning

The growth of electric vehicles is particularly relevant to ro-ro (Roll on Roll Off) and vehicle-carrier operations. In 2024, the International Maritime Organization (IMO) began a dedicated work programme on the fire safety of ships carrying  electric vehicles. Its scope included the hazards associated with battery-electric vehicles, gaps in existing regulations, and the functional requirements needed for detection, control, containment, and suppression. 

That work reflects a risk profile that is still developing. A battery cell can enter thermal runaway when heat generation becomes self-sustaining. Heat can then propagate to adjacent cells or modules, while flammable and toxic gases are released. Even when visible flames have been extinguished, stored energy and internal damage leave a continuing risk of re-ignition. 

This does not make every lithium-ion incident identical. Battery chemistry, level of charge, pack design, mechanical damage, and the surrounding space all influence how an event develops. Procedures built around a single assumed fire curve or one standard response create false confidence. Planning must focus on observable conditions, clear decision points, and the reality that an incident can escalate faster than expected. 

The First Safety Gap Is Knowing What Is On Board

Fire plans are only as good as the cargo information behind them. In September 2026, a World Shipping Council warning highlighted a gap in Special Provision 188 of the International Maritime Dangerous Goods Code. Smaller lithium cells and batteries can qualify for exemptions when they meet specified testing, packaging and capacity criteria, yet the provision does not currently cap how many qualifying batteries may be consolidated in one cargo transport unit. 

The WSC illustrated the scale with a container holding about 4,200 laptops. It estimated that the batteries could represent approximately 416 kWh of stored energy, comparable with three or four electric vehicles, without dangerous-goods documentation or container placarding being required. The point is not that exempt shipments are inherently unsafe. Properly tested, packed and declared batteries move safely every day. The problem is that a significant combined hazard can be ‘invisible’ to the carrier, crew, port and emergency responders. 

That visibility gap reaches directly into emergency planning. If responders do not know the type, location or scale of the battery load, decisions about stowage, ventilation, boundary cooling, exclusion zones, retreat points and protected escape routes may be based on an incomplete picture. The WSC proposal for a container-level threshold remains part of an international regulatory discussion, but the operational principle is useful now: a ship’s Safety Management System should test how battery information is obtained, checked and translated into the voyage-specific fire plan, including where individually exempt devices may create a material combined exposure. 

What Thermal Runaway Changes On Board

A conventional vehicle fire and an electric vehicle fire share many hazards, including heat, smoke, and burning interior materials. The operational difference is that thermal runaway can continue deep within a battery pack and will not be stopped by extinguishing surface flames. Cooling, boundary protection, continuous monitoring, and controlling adjacent spaces often remain necessary long after the main fire appears to be out. 

Research reviewed by the European Maritime Safety Agency (EMSA) shows why early warning is rarely straightforward.  Gas released before or during thermal runaway moves through a vehicle deck in ways that challenge conventional ceiling-mounted smoke detectors,particularly when cool, dense gases spread laterally or settle in low deck areas. Before ignition ever occurs, these unignited vapour clouds pose severe toxic hazards and can trigger sudden flash fires or vapour cloud explosions (VCE). Thermal imaging and early gas detection help provide early warning, but no single sensor replaces trained crew interpretation and a coordinated response. 

Suppression systems face similar limits. Tests and real-world incidents show that sustained cooling is critical, and any fixed system’s success depends heavily on the space layout, fire location, and overall system design. Crews must understand what their equipment can realistically achieve, recognise the warning signs of escalation, and know when continued manual intervention puts lives at risk. 

Smoke and Gas Can Make Escape the Immediate Problem

For anyone trying to clear an affected deck, the primary threat to life is often the atmosphere rather than direct flame. Battery incidents produce carbon monoxide, carbon dioxide, volatile organic compounds, and hydrogen gas. Crucially, they can also release highly corrosive acid gases like Hydrogen Fluoride (HF), which causes severe respiratory damage even in low concentrations. Because this gas mixture varies from fire to fire, crews should never assume an atmosphere is safe just because a single target gas is absent. 

Dense smoke and vapour clouds also destroy essential visual cues. Deck markings, vehicle lanes, doorways, and low-level obstacles disappear, while heat, toxic irritation, and panic reduce the time available for clear thinking. On a packed vehicle deck, an escape route that seems obvious during a routine walk-through can quickly become impassable in heavy smoke. 

Ventilation choices directly affect this hazard. Adjusting air flow impacts smoke movement, heat buildup, flammable gas buildup, and whether adjacent escape routes stay usable. Because the right action depends on the exact scenario, emergency plans should clearly state: 

  • Who has the authority to change ventilation settings. 
  • What specific information triggers that decision. 
  • How crew members will monitor whether active escape routes remain safe. 

Detection and Suppression Do Not Complete the Response

New requirements from January 2026 mandate stronger fire detection, alarm, and monitoring systems for vehicle, special category, and ro-ro spaces under SOLAS amendments. While these updates are an important step forward, installed equipment is only part of the solution. An alarm alerts the bridge; it cannot decide whether a fire team can safely approach, whether an exit path remains clear, or when it is time to evacuate. 

Regulations are also changing rapidly. At its March 2026 session, the IMO Sub-Committee on Ship Systems and Equipment (SSE) set priority measures for new-energy vehicle safety while working toward future mandatory rules and guidance. Because standards are evolving, operators should treat lithium-ion risk assessments as active working documents rather than one-off paperwork. 

Feedback from drills, near misses, cargo changes, and equipment modifications should directly update the plan. The same applies to new guidance from flag states, classification societies, insurers, and maritime authorities. The goal is to consistently verify that assumptions about detection, access, firefighting, and escape hold up under actual operating conditions. 

Recent Maritime Professional Council guidance makes the same issue broader than firefighting technique. It calls for stronger regulation, battery-specific crew training and coordination between operators, regulators, manufacturers and emergency responders. On board, that coordination must be practical: the bridge and response teams need the same cargo picture; drills must expose weak handovers; and shore responders need timely information about cargo location, temperature, atmosphere and actions already taken. A procedure can look complete on paper and still fail at the point where information passes from one party to another. 

What Vessel Operators Should Reassess 

An effective review looks at actual voyages and specific ship designs rather than relying on generic battery-fire checklists. Operators need clear answers to four questions: 

  • What battery-powered cargo is on board, and where is it stowed? 
  • What does the cargo declaration reveal, and could individually exempt devices create a significant combined battery load? 
  • What charging or operational restrictions apply? 
  • How would a fire in that specific location impact crew members and escape routes across the ship? 

Escape routes should then be tested against realistic smoke, toxic gas, and access scenarios. This means verifying that main and alternative exits stay clear during cargo operations, that doors and hatches open quickly, and that smoke will not pull into safe areas through ventilation intakes. Plans must also account for drivers, contractors, or passengers who do not know the ship layout. 

Drills work best when they force people to make decisions rather than walk a familiar path. Scenario training should: 

  • Block normal exit paths or delay confirmation of where the fire started. 
  • Force response teams to fall back when conditions worsen. 
  • Test comms between the bridge, engine room, and emergency response teams. 
  • Test the handover of cargo, stowage and atmospheric information to shore-based responders. 
  • Practice headcounts and prevent anyone from re-entering contaminated areas. 

Finally, emergency plans must link firefighting directly to escape. That requires clear triggers for calling a retreat, an established way to broadcast that command, and protective gear stored where people can actually reach it before stepping into smoke. If an escape device sits behind a hazard or under lock and key, its presence on an inventory list offers zero real-world protection. 

The Role of EEBDs in Lithium-Ion Fire Preparedness

An Emergency Escape Breathing Device (EEBD) supplies clean air or oxygen so a person can escape a toxic or oxygen-deficient atmosphere. Under Chapter 3 of the IMO Fire Safety Systems (FSS) Code, an EEBD is strictly for escape. Standard approved units are built to supply at least 15 minutes of breathable air. They are not designed for fighting fires, investigating compartments, or rescues. Every crew member must understand this limit, because putting on an escape hood does not make it safe to enter an active fire zone. 

In Lithium-ion emergency plans, EEBDs fit into a broader safety system alongside cargo information, alarms, containment, suppression, layout design, bridge commands and training. Deciding where to store devices should reflect how long it actually takes to reach clean air under worst-case conditions, taking into account delays, total darkness, toxic gas accumulation and blocked exits. 

Placement should also be reviewed against the locations of declared battery cargo and credible uncertainty in the cargo picture, not only against a static deck plan. With a 15-minute air limit, workers must be able to grab, don and move without hesitation, which requires hands-on practice in low light and high-stress drills. 

 Any change to deck layouts, vehicle parking, or battery storage should immediately trigger a check to confirm escape gear remains within reach. 

Preparing for an Evolving Risk

The WSC and MPC interventions point to a connected weakness: cargo information, equipment, training and escape are often managed as separate subjects. The perspective from Semmco LPS is that escape planning should connect them. Cargo visibility should inform stowage, monitoring and ventilation decisions; those decisions should set retreat criteria and protect escape routes; and the route assessment should determine where EEBDs are placed and how drills are run. Operators do not need to wait for every regulatory question to be settled before testing those links on their own vessels. 

Semmco LPS works with marine organisations to review emergency escape routes and respiratory protection as part of complete life-safety planning. For technical guidance on marine applications and escape breathing apparatus, contact our team to discuss your vessel’s specific layout and risk profile. 

Related FAQs

Why does undeclared battery cargo matter at sea?

When a battery load is undeclared or its combined scale is not visible, the carrier and crew may be unable to choose appropriate stowage, protect adjacent spaces or prepare the right response. Responders may not know what is burning, where it is located or how much stored energy is involved. The result is a slower and less certain assessment at the moment when ventilation, approach, retreat and escape decisions need to be made quickly. 

What is thermal runaway in a lithium-ion battery?

Thermal runaway is a chain reaction where a battery cell’s internal temperature rises uncontrollably. Triggered by physical damage, electrical faults, or external heat, the cell vents toxic and flammable gases while dumping heat into surrounding cells. Because surface flames are only part of the problem, cooling and atmospheric monitoring must continue long after the fire looks extinguished. 

Why do lithium-ion battery fires re-ignite?

Chemical reactions and trapped heat can persist deep inside a battery pack after surface flames are put out. If hot cells remain uncooled or transfer energy to neighbouring modules, the fire can restart without warning. Preventing re-ignition requires post-fire temperature checks, electrical isolation, boundary cooling, and a continuous fire watch. 

What breathing hazards do battery fires create?

Battery fires release thick smoke along with carbon monoxide, carbon dioxide, hydrogen, volatile organic compounds, and highly toxic acid gases like Hydrogen Fluoride (HF). Before flames even appear, off-gassing can form dense, low-lying gas clouds that present extreme inhalation risks and flash-fire hazards. Treat any unventilated atmosphere near a battery incident as immediately dangerous. 

What is the role of an EEBD during a lithium-ion fire?

An EEBD gives a person a short supply of clean air (typically 15 minutes under IMO rules) to escape a toxic space. It is an escape tool only and must never be used to fight fires or carry out rescues. An EEBD is only as good as its location, maintenance, and how quickly a trained crew member can put it on in an emergency.